979 resultados para imaging quality


Relevância:

80.00% 80.00%

Publicador:

Resumo:

L. Blot, A. Davis, M. Holubinka, R. Marti and R. Zwiggelaar, 'Automated quality assurance applied to mammographic imaging', EURASIP Journal of Applied Signal Processing 2002 (7), 736-745 (2002)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We use coherent-mode representation of partially coherent fields to analyze correlated imaging with classical light sources. This formalism is very useful to study the imaging quality. By decomposing the unknown object as the superposition of different coherent modes, the components corresponding to small eigenvalues cannot be well imaged. The generated images depend crucially on the distribution of the eigenvalues of the coherent-mode representation of the source and the decomposition coefficients of the objects. Three kinds of correlated imaging schemes are analyzed numerically.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A novel acousto-optic spectrometer (IfU Diagnostic Systems GmbH) for 2-dimensional (2D) optical emission spectroscopy with high spectral resolution has been developed. The spectrometer is based on acousto-optic tuneable filter technology with fast random wavelength access. Measurements for characterisation of the imaging quality, the spatial resolution, and the spectral resolution are presented. The applicability for 2D-space and phase resolved optical emission spectroscopy (2D-PROES) is shown. 2D-PROES has been applied to an inductively coupled plasma with radio frequency excitation at 13.56 MHz.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE:Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo.MATERIALS AND METHODS:Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm.RESULTS:Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures.CONCLUSIONS:This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background and purpose: Trans-Tasman Radiation Oncology Group 96.05 is a prospective randomized controlled trial comparing a single 8 Gy with 20 Gy in five fractions of radiotherapy (RT) for neuropathic pain due to bone metastases. This paper summarizes the quality assurance (QA) activities for the first 234 patients (accrual target 270). Materials and methods: Independent audits to assess compliance with eligibility/exclusion criteria and appropriateness of treatment of the index site were conducted after each cohort of approximately 45 consecutive patients. Reported serious adverse events (SAEs) in the form of cord/cauda equina compression or pathological fracture developing at the index site were investigated and presented in batches to the Independent Data Monitoring Committee. Finally, source data verification of the RT prescription page and treatment records was undertaken for each of the first 234 patients to assess compliance with the protocol. Results: Only one patient was found conclusively not to have genuine neuropathic pain, and there were no detected 'geographical misses' with RT fields. The overall rate of detected infringements for other eligibility criteria over five audits (225 patients) was 8% with a dramatic improvement after the first audit. There has at no stage been a statistically significant difference in SAEs by randomization arm. There was a 22% rate of RT protocol variations involving ten of the 14 contributing centres, although the rate of major dose violations (more than +/- 10% from protocol dose) was only 6% with no statistically significant difference by randomization arm (P = 0.44). Conclusions: QA auditing is an essential but time-consuming component of RT trials, including those assessing palliative endpoints. Our experience confirms that all aspects should commence soon after study activation. Crown Copyright (C) 2003 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel method for measuring the imaging quality of a projection system with mirror-symmetric FOCAL marks is proposed, and the principle of the method is described. Through experiments, it is demonstrated that not only the axial aberrations but also the lateral aberrations can be measured with high accuracy by the method. The advantages of the method include obtaining more aberrations than the FOCAL technique and making it much simpler to perform a full-scale measurement of the imaging quality of a lithographic projection system. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel method for measuring the imaging quality of a projection system with mirror-symmetric FOCAL marks is proposed, and the principle of the method is described. Through experiments, it is demonstrated that not only the axial aberrations but also the lateral aberrations can be measured with high accuracy by the method. The advantages of the method include obtaining more aberrations than the FOCAL technique and making it much simpler to perform a full-scale measurement of the imaging quality of a lithographic projection system. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We design three-zone annular filters to be applied to optical storage system. The designed filters extend the depth of focus and realize transverse superresolution simultaneously, which will improve the performance of optical storage system greatly. And we propose two feasible schemes to improve imaging resolution of three-dimensional imaging system. One scheme depends on a complex filter formed by cascading of a three-zone phase filter and a three-zone amplitude filter. The complex filter converge the optimized transverse superresolution and the optimized axial superresolution of two different filters onto a single filter. It can improve the three-dimensional imaging performances greatly. Another scheme depends on a single three-zone complex filter. We propose a three-zone complex filter with phase shift 0.8 pi, which presents bigger design margin, better imaging quality and stronger three-dimensional superresolution capability. (c) 2006 Elsevier GmbH. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel structure of MMI coupler with different background refractive index has been designed. With stronger optical confinement in multimode waveguides, more guided modes are excited to improve imaging quality. Two-dimensional finite difference beam propagation method (2-D FDBPM) was used to simulate this new structure and had proven that its imaging quality, in terms of power uniformity and excess loss, is much better than conventional structure. This structure can be applied in SOI rib waveguides by deep etching method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The practice of geophysical prospecting shows us the complex interior earth. The studies of the complexity play an important role and practical guide for the subsurface structure. At present, the complexity of the earth mainly means lateral and vertical homogeneity, anisotropy and non-linear quality. And the anisotropy and non-linear media studies become the frontier in seismology and exploration seismology. This paper summarizes the development of complexities and presents the forward and inverse in the non-linear and anisotropic media. Firstly, the paper introduces the theory of seismic wave propagation in the non-linear and anisotropic media, the theoretical basis for simulation and inversion research. Secondly, high quality numerical simulation method with little dispersion has been developed to investigate the influence of complexity including anisotropy and non-linear multi-component seismograms. Because most real data in seismology have a single component, we developed two aspects work on anisotropic multi-component imaging. One is prestack reflection migration. The result show that distorted images are obtained if data from anisotropic media are migrated using isotropic extrapolation. Moreover, image quality will be improved greatly after considering anisotropy in subsurface layers. The other one is the we take advantage of multi-component data to inversion of the anisotropic parameters jointly seimic reflection travel time and polarization information. Based on these research works, we get the following results: 1.Combing numerical simulation, systematical studies indicate that anisotropy and non-linear seismograms characters are significant to detect cracked belts in the earth and to understand deformation field and mechanism. 2.Based on anisotropic media models, we developed an efficient prestack migration method for subsurface structure and different observation methods seismic data, which improving the imaging quality with VSP, seismograms and real data. 3.Jointly seismic inversion combining seismic anisotropic reflection traveltimes and polarizations data show that the complete wrong inversion and the following explanation will be resulted by ignoring anisotropy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present new Herschel photometric and spectroscopic observations of Supernova 1987A, carried out in 2012. Our dedicated photometric measurements provide new 70 mu m data and improved imaging quality at 100 and 160 mu m compared to previous observations in 2010. Our Herschel spectra show only weak CO line emission, and provide an upper limit for the 63 mu m [O-I] line flux, eliminating the possibility that line contaminations distort the previously estimated dustmass. The far-infrared spectral energy distribution (SED) is well fitted by thermal emission from cold dust. The newly measured 70 mu m flux constrains the dust temperature, limiting it to nearly a single temperature. The far-infrared emission can be fitted by 0.5 +/- 0.1M(circle dot) of amorphous carbon, about a factor of two larger than the current nucleosynthetic mass prediction for carbon. The observation of SiO molecules at early and late phases suggests that silicates may also have formed and we could fit the SED with a combination of 0.3M(circle dot) of amorphous carbon and 0.5M(circle dot) of silicates, totalling 0.8M(circle dot) of dust. Our analysis thus supports the presence of a large dust reservoir in the ejecta of SN 1987A. The inferred dust mass suggests that supernovae can be an important source of dust in the interstellar medium, from local to high-redshift galaxies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Especificar e quantificar as principais falhas técnicas, sejam elas eletrônicas ou mecânicas, presentes em radiografias convencionais de tórax, com o intuito de melhorar a sua qualidade e reduzir a necessidade da repetição dos exames e, consequentemente, a dose recebida pelo paciente. MATERIAIS E MÉTODOS: Foram selecionadas e avaliadas por um pneumologista 897 radiografias convencionais realizadas ou em projeção posteroanterior ou lateral em cinco instituições de saúde da cidade de São Paulo. em cada uma delas foram feitas análises das falhas técnicas presentes, as quais foram classificadas de acordo com o erro técnico radiográfico pré-definido e que levou à repetição do exame. RESULTADOS: Os resultados obtidos mostraram que o posicionamento incorreto do paciente (27%), a subexposição (23%) e a superexposição (15%) foram as principais falhas que contribuíram para a repetição dos exames e que apresentaram, na matriz de coeficiente de correlação Pearson, um erro acima de 0,7%, ocasionando aumento da dose recebida pelos pacientes. CONCLUSÃO: Os resultados observados indicaram a necessidade da realização de controle de qualidade dos aparelhos de raios X, a atenção do operador do equipamento, bem como outras abordagens para esclarecer o impacto da necessidade de repetição do exame.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The tapping mode is one of the mostly employed techniques in atomic force microscopy due to its accurate imaging quality for a wide variety of surfaces. However, chaotic microcantilever motion impairs the obtention of accurate images from the sample surfaces. In order to investigate the problem the tapping mode atomic force microscope is modeled and chaotic motion is identified for a wide range of the parameter's values. Additionally, attempting to prevent the chaotic motion, two control techniques are implemented: the optimal linear feedback control and the time-delayed feedback control. The simulation results show the feasibility of the techniques for chaos control in the atomic force microscopy. © 2012 IMechE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the neuroimaging quality and accuracy of prospective real-time navigator-echo acquisition correction versus untriggered intrauterine magnetic resonance imaging (MRI) techniques. Twenty women in whom fetal motion artifacts compromised the neuroimaging quality of fetal MRI taken during the 28.7 +/- 4 week of pregnancy below diagnostic levels were additionally investigated using a navigator-triggered half-Fourier acquired single-shot turbo-spin echo (HASTE) sequence. Imaging quality was evaluated by two blinded readers applying a rating scale from 1 (not diagnostic) to 5 (excellent). Diagnostic criteria included depiction of the germinal matrix, grey and white matter, CSF, brain stem and cerebellum. Signal-difference-to-noise ratios (SDNRs) in the white matter and germinal zone were quantitatively evaluated. Imaging quality improved in 18/20 patients using the navigator echo technique (2.4 +/- 0.58 vs. 3.65 +/- 0.73 SD, p < 0.01 for all evaluation criteria). In 2/20 patients fetal movement severely impaired image quality in conventional and navigated HASTE. Navigator-echo imaging revealed additional structural brain abnormalities and confirmed diagnosis in 8/20 patients. The accuracy improved from 50% to 90%. Average SDNR increased from 0.7 +/- 7.27 to 19.83 +/- 15.71 (p < 0.01). Navigator-echo-based real-time triggering of fetal head movement is a reliable technique that can deliver diagnostic fetal MR image quality despite vigorous fetal movement.